Below is an image of what a user sees to start the quoting process.
Search the home inspection database to help users build their request forms.
Main | Minor | Repair Item | tags | Lo | Avg | Hi | Unit | Notes | Safety item |
---|---|---|---|---|---|---|---|---|---|
Site and Grounds | Landscaping | Trim overgrown vegetation from contact with house | landscaping, tree trimming, overgrowth | 265 | 265 | 265 | NO | ||
Site and Grounds | Landscaping | Irrigation service includes up to 5 leaks, 5 heads, no valves, other minor repairs and then system testing | irrigation leaks, irrigation valves, irrigation testing | 210 | 237.5 | 265 | NO | ||
Site and Grounds | Landscaping | Replace irrigation valve | irrigation valve | 45 | 60 | 75 | Assumes no equipment replacement | NO | |
Site and Grounds | Grading and Draining | Correct grading slope to foundation known as negative grade | grading and draining foundation, foundation, negative grade, foundation slope | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Site and Grounds | Grading and Draining | Reduce soil/gravel at building perimeter to expose stem wall | stem wall | 20 | 20 | 20 | Sq. Ft. | NO | |
Site and Grounds | Grading and Draining | Correct poor draining at patio surface | drain at patio, patio drainage, | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Site and Grounds | Grading and Draining | Add drainage blocks; no visible drains, | drain blocks; draining | 500 | 550 | 600 | Assumes 50-100 ft. of wall; every 10'-20' | NO | |
Site and Grounds | Grading and Draining | Add perimeter channel drains | channel drains, perimeter drains, perimeter channel drains | 1000 | 1250 | 1500 | Assumes 50-100 ft. of wall | NO | |
Site and Grounds | Fencing | WOOD FENCE ~ Repair deteriorated wood slats at gate | wood fence, slates on fence, wood slates | 120 | 120 | 120 | Assumes gate is smaller than 6 ft. | NO | |
Site and Grounds | Fencing | POOL FENCE ~ Install fence around pool; install a barrier or fence between home and pool area | pool fence, pool barrier | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | YES | |
Site and Grounds | Fencing | WROUGHT IRON ~ Secure fencing to posts | wrought iron, fence, posts | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Site and Grounds | Patio | Repair damaged drywall on porch ceiling (texture to match existing texture) | drywall patio ceiling | 750 | 750 | 750 | Price assumes painting of a 8' x 12' patio | NO | |
Site and Grounds | Drive / Walks | Repair trip hazard | walkway | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | YES | |
Site and Grounds | Drive / Walks | Repair driveway | concrete driveway | 9 | 9 | 9 | Sq. Ft. | Assume concrete is 2500 psi; does not include demolition or termite pretreatment | NO |
Site and Grounds | Drive / Walks | Chemical power wash concrete in driveway | power wash driveway | 320 | 320 | 320 | NO | ||
Site and Grounds | Gates | Repair gate latch on existing block gate | block gate, gate latch | 110 | 120 | 130 | Qty | NO | |
Site and Grounds | Gates | Install self- closing hardware | self closing gate, gate latch | 150 | 165 | 180 | Qty | NO | |
Site and Grounds | Gates | Replace wood gate slats | wood slats gate | 375 | 375 | 375 | NO | ||
Site and Grounds | Gates | Resecure metal gate posts to block wall | gate post | 135 | 135 | 135 | Qty | Safety issue if gate is at entrance to pool area | YES |
Site and Grounds | Stoop / Steps | Repair stoops/steps | stoops, steps | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | YES | |
Exterior | Structure & Cladding | STUCCO ~ Repair/replace wall cladding on exterior of home | stucco house wall, exterior stucco wall, exterior wall cladding stucco | 420 | 535 | 650 | Assumes 1/2" build out of stucco; Pricing does not include painting of stucco (see Exterior/ Paint for quote) | NO | |
Exterior | Structure & Cladding | SIDING ~ Repair/replace wall cladding on exterior of home | siding house wall, exterior siding wall, exterior wall cladding siding | 225 | 225 | 225 | # Sheets | Pricing does not include painting of siding (see Exterior/ Paint for quote) | NO |
Exterior | Structure & Cladding | BLOCK ~ Repair deteriorated blocks at wall | block wall, exterior wall, | 550 | 550 | 550 | Repair common and moderate cracks in block fence | NO | |
Exterior | Paint | Exterior of house at end of life; budget for a paint job | painting, paint, exterior | 1.25 | 1.5 | 1.75 | Sq. Ft. | NO | |
Exterior | Paint | Exterior touch-up paint, up to 10' x 10' | painting, paint, exterior | 325 | 325 | 375 | Matching of paint may not be possible due to exposure to elements | NO | |
Exterior | Fascia/Eaves and Soffits | Replace dry rotted wood at fascia | fascia, dry rotted fascia | 35 | 45 | 55 | LF | Linear Feet obtained from County Accessor's Office; Does not include painting (see Exterior/ Paint for quote) | NO |
Exterior | Fascia/Eaves and Soffits | Repair dry rotted wood at fascia with hard putty filler | fascia, dry rotted fascia | 15 | 20.5 | 26 | LF | Linear Feet obtained from County Accessor's Office; Does not include painting (see Exterior/ Paint for quote) | NO |
Exterior | Paint | Paint eaves to protect from elements; moisture staining at eaves | eaves paint, painting, eaves | 9.5 | 10.75 | 12 | Sq. Ft. | NO | |
Exterior | Paint | Stain exterior door | front door stain | 250 | 350 | 450 | Qty | NO | |
Exterior | Paint | Paint exterior door | front door paint | 250 | 300 | 350 | Qty | NO | |
Exterior | Doors | SLIDING DOOR ~ Repair exterior door to latch and to lock | Arcadia, sliders, sliding doors | 125 | 135 | 145 | Qty | Assume replace only; not repair; dependent on door style; standard 6' slider | NO |
Exterior | Doors | SLIDING DOOR ~ Install/replace patio sliding door | Arcadia, sliders, sliding doors | 960 | 1130 | 1300 | Qty | Assumes 6'0 x 6'8 patio door; standard builder grade door; hardware for self closing. Includes interior and exterior trim; does not include drywall/ stucco repair or paint | NO |
Exterior | Doors | SLIDING DOOR ~ Add self-closer to sliding door | Arcadia, sliders, sliding doors | 150 | 170 | 190 | Qty | YES | |
Exterior | Doors | SLIDING DOOR ~ Inspect, adjust/repair sliding door rollers | Arcadia, sliders, sliding doors | 195 | 227.5 | 260 | Qty | NO | |
Exterior | Doors | SCREEN DOOR ~ Replace torn exterior door screen material | Arcadia, sliders, screen doors | 95 | 110 | 125 | Qty | NO | |
Exterior | Doors | SCREEN DOOR ~ Install/replace sliding screen (patio) door | Arcadia, sliders, screen doors | 190 | 207.5 | 225 | Qty | Assumes replace door only; usually prehung door | NO |
Exterior | Doors | JAM ~ Repair rotted exterior door jam | jam, door trim, door jam | 135 | 157.5 | 180 | Qty | Does not include painting (see Exterior/ Paint for quote) | NO |
Exterior | Doors | LOCKS ~ Replace keyed dead bolts with thumb latch locks | dead bolts, locks | 150 | 210 | 270 | Qty | Price assumes standard locks | NO |
Exterior | Doors | Replace weather stripping on exterior door | weather stripping | 85 | 130 | 175 | Qty | Does not include threshold | NO |
Exterior | Doors | Repair door that sticks in frame | door frame | 150 | 150 | 150 | Qty | NO | |
Exterior | Doors | FRONT DOOR ~ Replace customer provided front door | front door | 450 | 625 | 800 | Qty | Does not include painting or staining of door (see Exterior/ Paint for quote) | NO |
Exterior | Doors | FRENCH DOOR ~ Repair French door that sticks in frame | French door | 135 | 165 | 195 | Qty | NO | |
Exterior | Doors | FRENCH DOOR ~ Replace customer provided French doors | French door | 400 | 560 | 720 | Qty | Does not include painting or staining of door (see Exterior/ Paint for quote) | NO |
Exterior | Doorbell | Replace doorbell: button only | doorbell, doorbell button | 75 | 85 | 95 | Qty | Does not include electrical wiring issues | NO |
Exterior | Doorbell | Replace doorbell: button and chime only | doorbell, doorbell button, doorbell chime | 75 | 75 | 75 | Qty | NO | |
Exterior | Doorbell | Replace doorbell: button, chime and low voltage transformer | doorbell, doorbell button, doorbell chime, transformer | 75 | 137.5 | 200 | Qty | NO | |
Exterior | Fixtures | Secure exterior light fixture | exterior light fixture, lighting | 65 | 75 | 85 | Qty | NO | |
Exterior | Fixtures | Caulk and seal exterior fixtures | caulk, seal, exterior lighting, light fixture | 95 | 110 | 125 | Qty | NO | |
Structure | Stem Wall | Correct spalling or deterioration of the concrete stem wall | stem wall, concrete wall, block wall | 45 | 55 | 65 | LF | Linear Feet obtained from County Accessor's Office; does not include painting (see Stem Wall / Paint for quote) | NO |
Structure | Stem Wall | Repair moderate cracks in stem (block) wall (larger than 1/4") | stem wall, concrete wall, block wall | 35 | 45 | 55 | LF | Linear Feet obtained from County Accessor's Office; does not include painting (see Stem Wall / Paint for quote) | NO |
Structure | Stem Wall | Secure caps to columns | stem wall, concrete wall, block wall | 85 | 85 | 85 | Qty | NO | |
Structure | Stem Wall | Paint stem wall where repaired | stem wall, concrete wall, block wall, paint | 5 | 5.5 | 6 | LF | Linear Feet obtained from County Accessor's Office | NO |
Structure | Stem Wall | Repair minor cracks in stem (block) wall; peeling paint (includes sanding and re-painting) | stem wall, concrete wall, block wall, paint | 450 | 500 | 550 | Assumes up to 30 linear feet | NO | |
Roof | Roof Inspection | Roof Inspection 1,200 sq. ft. - 10,000 sq. ft. | roof inspection, roofing inspection | 175 | 337.5 | 500 | NO | ||
Roof | Roof Water Test | Roof water test | roof leak test, roofing water test | 225 | 275 | 325 | NO | ||
Roof | Roof Drainage | Replace/ Install drip edge | drip edge | 5 | 7.5 | 10 | LF | Linear Feet obtained from County Accessor's Office | NO |
Roof | Roof Penetrations | Repair roof penetrations (vents) | roof penetration, roof vent, collar, flue, | 95 | 102.5 | 110 | Qty | NO | |
Roof | Roof Penetrations | Seal roof penetrations (vent) | roof penetration, roof vent, collar, flue, | 95 | 102.5 | 110 | Qty | NO | |
Roof | Roof Penetrations | Repair plumbing flue vent pipe | vent pipe, flue pipe, roof penetration, collar | 125 | 125 | 125 | NO | ||
Roof | Roof Penetrations | Repair gas appliance flue vent pipe | vent pipe, flue pipe, roof penetration, collar | 125 | 125 | 125 | NO | ||
Roof | Roof Tiles | Replace individual roof tile (each) | broken tiles, concrete tiles | 25 | 25 | 25 | Qty | NO | |
Roof | Roof Tiles | Roof tile service includes repair/ replacement of up to 25 broken tiles, repacking of mud balls and clean debris from valleys (does not include plywood repair) | broken tiles, concrete tiles, mud balls, valleys | 525 | 637.5 | 750 | NO | ||
Roof | Flashing | Install saddle/cricket flashing at chimney | flashing, shingle roof | 500 | 650 | 800 | NO | ||
Roof | Skylights | Replace skylight: Plastic | skylight | 350 | 475 | 600 | Qty | NO | |
Roof | Skylights | Replace skylight: Glass | skylight | 425 | 537.5 | 650 | Qty | NO | |
Roof | Roof Drainage | Clean gutters: assumes single story, 40-50' | gutters | 150 | 162.5 | 175 | NO | ||
Roof | Roof Drainage | Clean gutters: whole assumes two stories, full perimeter | gutters | 500 | 500 | 500 | NO | ||
Roof | Roof Drainage | Add gutters: assumes one story | gutters | 7.5 | 9.25 | 11 | LF | Linear Feet obtained from County Accessor's Office | NO |
Roof | Roof Repair | Replace any damaged/flawed roof decking | roof decking | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Roof | Roof Repair | Seal perimeter of back patio (flat roof) to prevent further leakage | seal perimeter, back patio roof, flat roof | 315 | 315 | 315 | Sq. Ft. | Assumes rolled roof | NO |
Roof | Roof Repair | Remove debris from all valleys | debris, roofing | 150 | 200 | 250 | Depends on type of debris, bird droppings have an increased cost; assumes 1,200-5,000 sq. ft. | NO | |
Roof | Roof Repair | Remove bird debris from rotating fan on roof | debris, roofing | 150 | 200 | 250 | NO | ||
Roof | Roof Repair | Seal top of parapet wall that is cracked to prevent moisture intrusion | parapet wall, roofing | 35 | 42.5 | 50 | LF | Linear Feet obtained from County Accessor's Office | NO |
Roof | Roof Repair | Install nails at roof perimeter (3 courses) | nailing rood perimeter | 4.5 | 4.5 | 4.5 | LF | Linear Feet obtained from County Accessor's Office | NO |
Roof | Roof Repair | Repair mortar caps (mud balls) to reduce potential for moisture to penetrate roof surface: 1-2 mortar caps (mud balls) | mortar caps, mud balls | 125 | 125 | 125 | NO | ||
Roof | Roof Repair | Repair mortar caps (mud balls) to reduce potential for moisture to penetrate roof surface: 10 mortar caps (mud balls) | mortar caps, mud balls | 250 | 250 | 250 | NO | ||
Roof | Roof Repair | Repair and recoating of foam roof | foam roof | 205 | 205 | 205 | Sq. Ft. | NO | |
Roof | Roof Replacement | 3 Tab Shingle Roof | 3 Tab Shingle Roof, re-roof | 285 | 285 | 285 | Sq. Ft. | NO | |
Roof | Roof Replacement | Dimensional Shingle Roof | Dimensional Shingle Roof | 315 | 315 | 315 | Sq. Ft. | NO | |
Roof | Roof Replacement | Concrete Tile Roof | Concrete Tile Roof | 325 | 325 | 325 | Sq. Ft. | NO | |
Roof | Roof Replacement | Clay Tile and Sand Cast Roof | Clay Tile and Sand Cast Roof | 435 | 435 | 435 | Sq. Ft. | NO | |
Roof | Roof Replacement | Flat Roof | Flat Roof | 295 | 295 | 295 | Sq. Ft. | NO | |
Electrical System | Inspect Electrical System | Inspect electrical system: 1-2 hours | electric inspection, electrical inspection, electrician | 85 | 127.5 | 170 | YES | ||
Electrical System | Inspect Electrical System | Inspect electrical system: entire home | electric inspection, electrical inspection, electrician | 200 | 250 | 300 | YES | ||
Electrical System | Main Electrical Panel | Repair antioxidant material on aluminum wire at main panel (1-2 circuits) | antioxidant, aluminum wire | 85 | 117.5 | 150 | YES | ||
Electrical System | Main Electrical Panel | Secure loose electrical panel to wall | electrical panel | 180 | 327.5 | 475 | Qty | YES | |
Electrical System | Main Electrical Panel | Repair cracked/separated service entrance conduit/lateral below main electrical panel | service entrance conduit, lateral | 185 | 530 | 875 | Need power company to shut off power | YES | |
Electrical System | Main Electrical Panel | Seal open slot in electrical panel dead-front cover | electrical panel, front cover | 85 | 105 | 125 | Qty | YES | |
Electrical System | Main Electrical Panel | Seal open knock-out hole in electrical panel (Missing breaker in panel needs knock out cover) | electrical panel | 85 | 117.5 | 150 | Qty | YES | |
Electrical System | Main Electrical Panel | Install approved circuit breaker | circuit breaker | 85 | 130 | 175 | Qty | YES | |
Electrical System | Main Electrical Panel | Repair double tap in breaker at main electrical panel and sub panel | double tap, breaker | 85 | 135 | 185 | YES | ||
Electrical System | Main Electrical Panel | Replace arc fault circuit interrupter (AFCI) breaker | arc fault circuit interrupter, AFCI, breaker | 185 | 375 | 565 | YES | ||
Electrical System | Main Electrical Panel | Label breakers on the dead front panel | label, breakers, dead front panel | 85 | 185 | 285 | Qty | YES | |
Electrical System | Main Electrical Panel | Install/replace breaker for specific wire size | breaker | 85 | 135 | 185 | Qty | YES | |
Electrical System | Main Electrical Panel | Install dedicated circuit for microwave | circuit, microwave | 650 | 825 | 1000 | Depends on location of microwave | YES | |
Electrical System | Main Electrical Panel | Replace GFCI breaker at main or sub panel | GFCI, breaker | 150 | 167.5 | 185 | Qty | YES | |
Electrical System | Main Electrical Panel | Wiring cleanup (does not include junction box) | exposed wiring, main breaker | 125 | 125 | 125 | Qty | YES | |
Electrical System | Wiring, Junction Boxes, & Conduit | Attic wire cleanup; place exposed wires in conduit; may include up to 2 junction boxes) | exposed wires, conduit | 225 | 225 | 275 | Includes wire splicing and 1 junction box installation | YES | |
Electrical System | Wiring, Junction Boxes, & Conduit | Repair incorrect wiring; polarity reversed | polarity reversed, incorrect wiring | 75 | 130 | 185 | Assumes using existing wiring | YES | |
Electrical System | Wiring, Junction Boxes, & Conduit | Replace bond wire from electrical panel to natural gas pipe | bond wire | 185 | 270 | 355 | Assumes gas pipe within 25 ft. of panel | YES | |
Electrical System | Wiring, Junction Boxes, & Conduit | Replace bond wire from electrical panel to water | bond wire | 185 | 270 | 355 | Assumes water main within 25 ft. of panel | YES | |
Electrical System | Wiring, Junction Boxes, & Conduit | Replace bond wire to the whirlpool pump motor in bathroom | bond wire | 130 | 130 | 130 | Qty | YES | |
Electrical System | Wiring, Junction Boxes, & Conduit | Seal junction box | junction box | 85 | 135 | 185 | Qty | YES | |
Electrical System | Wiring, Junction Boxes, & Conduit | Install junction box to contain exposed wires | exposed wires, conduit | 185 | 270 | 355 | Qty | Assumes easy access to box | YES |
Electrical System | Wiring, Junction Boxes, & Conduit | Install cover for junction box | junction box cover | 75 | 150 | 225 | Qty | Depends on location; Assumes in attic | YES |
Electrical System | Wiring, Junction Boxes, & Conduit | Install conduit for exposed wires (Indoor / outdoor - high voltage) | exposed wires, conduit | 180 | 267.5 | 355 | YES | ||
Electrical System | Wiring, Junction Boxes, & Conduit | Secure receptacle (outlet) junction box for oven | receptacle, outlet, junction box, oven | 85 | 135 | 185 | YES | ||
Electrical System | Wiring, Junction Boxes, & Conduit | Secure exposed and damaged wiring at water heater | wiring, water heater | 85 | 85 | 85 | YES | ||
Electrical System | Wiring, Junction Boxes, & Conduit | Wiring for low voltage (exterior lighting) | exterior lighting, low voltage, wiring | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Electrical System | Grounding GFCI Receptacles (Outlets) | Add GFCI receptacle (outlet) in pool light circuit | pool light, pool, GFCI | 125 | 162.5 | 200 | YES | ||
Electrical System | Grounding GFCI Receptacles (Outlets) | Installation/replacement of GFCI receptacle (outlet) | GFCI, receptacle, outlet | 85 | 105 | 125 | Qty | YES | |
Electrical System | Grounding GFCI Receptacles (Outlets) | Repair open ground: Ground present at receptacle (outlet) | GFCI, receptacle, outlet | 85 | 135 | 185 | Qty | YES | |
Electrical System | Grounding GFCI Receptacles (Outlets) | Repair open ground: Ground not present at receptacle (outlet) | GFCI, receptacle, outlet | 185 | 342.5 | 500 | Qty | YES | |
Electrical System | Receptacles (Outlets), Switches, & Fixtures | Install duplex receptacle (outlet) including cover | duplex, receptacle, outlet, cover | 65 | 65 | 65 | Qty | YES | |
Electrical System | Receptacles (Outlets), Switches, & Fixtures | Secure loose receptacle (outlet)/junction box | duplex, receptacle, outlet, junction box | 85 | 135 | 185 | Qty | YES | |
Electrical System | Receptacles (Outlets), Switches, & Fixtures | Replace missing receptacle (outlet) covers -interior | receptacle, interior outlet cover | 85 | 135 | 185 | Qty | YES | |
Electrical System | Receptacles (Outlets), Switches, & Fixtures | Replace missing receptacle (outlet) covers -exterior | receptacle, exterior outlet, cover | 60 | 65 | 70 | Qty | YES | |
Electrical System | Receptacles (Outlets), Switches, & Fixtures | Trouble shoot/repair inoperative receptacle (outlet) or fixture | receptacle, outlet | 105 | 302.5 | 500 | Qty | YES | |
Electrical System | Receptacles (Outlets), Switches, & Fixtures | Repair/replace broken, corroded, or loose conduit | conduit | 105 | 302.5 | 500 | Qty | Dependent on access | YES |
Electrical System | Receptacles (Outlets), Switches, & Fixtures | Rebalance ceiling fan to prevent wobble | ceiling fan | 95 | 95 | 95 | Qty | NO | |
Electrical System | Receptacles (Outlets), Switches, & Fixtures | Rough-in new ceiling fan | ceiling fans | 370 | 370 | 370 | Qty | Includes drywall repair and paint touch-up | NO |
Electrical System | Receptacles (Outlets), Switches, & Fixtures | Replace existing fans (using existing J - Box) | ceiling fans | 130 | 135 | 140 | Qty | Assumes rough-in new ceiling fan with new J-box | NO |
Heating & Cooling (HVAC) | Inspection / Diagnosis / Service Package | Inspect, diagnose and service (minor repairs) of tightening loose contacts, inspection of major parts of unit, evaluating splits, and further detailed recommendation of repairs needed. | air conditioning, air conditioner, inspection | 265 | 275 | 285 | Qty | Assumes coolant addition of 1 pound or less | NO |
Heating & Cooling (HVAC) | Cooling System | Temperature differential for cooling is incorrect | temperature differential | 185 | 255 | 325 | Repair item may not be specifically identified on the home inspection report; recommend an onsite inspection by a licensed HVAC expert | NO | |
Heating & Cooling (HVAC) | Cooling System | Add refrigerant (Freon) per pound discount avg. need 3 pounds | refrigerant, Freon | 120 | 120 | 120 | LBS | Repair item may not be specifically identified on the home inspection report; recommend an onsite inspection by a licensed HVAC expert | NO |
Heating & Cooling (HVAC) | Cooling System | Replacing dual run capacitor | dual run capacitor | 235 | 235 | 235 | Repair item may not be specifically identified on the home inspection report; recommend an onsite inspection by a licensed HVAC expert | NO | |
Heating & Cooling (HVAC) | Cooling System | Clean indoor coil | indoor coil | 350 | 350 | 350 | Repair item may not be specifically identified on the home inspection report; recommend an onsite inspection by a licensed HVAC expert | NO | |
Heating & Cooling (HVAC) | Cooling System | Replace contactor | contactor | 250 | 250 | 250 | Repair item may not be specifically identified on the home inspection report; recommend an onsite inspection by a licensed HVAC expert | NO | |
Heating & Cooling (HVAC) | Cooling System | Replace outdoor fan motor | fan motor | 550 | 550 | 550 | Qty | Repair item may not be specifically identified on the home inspection report; recommend an onsite inspection by a licensed HVAC expert | NO |
Heating & Cooling (HVAC) | Cooling System | Replace / repair Indoor blower motor | blower motor | 650 | 650 | 650 | Repair item may not be specifically identified on the home inspection report; recommend an onsite inspection by a licensed HVAC expert | NO | |
Heating & Cooling (HVAC) | Heating System | Add refrigerant (Freon) per pound discount for multiple poundage avg. need 3 pounds | refrigerant, Freon | 120 | 120 | 120 | LBS | Repair item may not be specifically identified on the home inspection report; recommend an onsite inspection by a licensed HVAC expert | NO |
Heating & Cooling (HVAC) | Heating System | Replace dual run capacitor | dual run capacitor | 235 | 235 | 235 | Repair item may not be specifically identified on the home inspection report; recommend an onsite inspection by a licensed HVAC expert | NO | |
Heating & Cooling (HVAC) | Heating System | Clean indoor coil | indoor coil | 350 | 350 | 350 | Repair item may not be specifically identified on the home inspection report; recommend an onsite inspection by a licensed HVAC expert | NO | |
Heating & Cooling (HVAC) | Heating System | Replace contactor | contactor | 250 | 250 | 250 | Repair item may not be specifically identified on the home inspection report; recommend an onsite inspection by a licensed HVAC expert | NO | |
Heating & Cooling (HVAC) | Heating System | Replace outdoor fan motor | fan motor | 550 | 550 | 550 | Repair item may not be specifically identified on the home inspection report; recommend an onsite inspection by a licensed HVAC expert | NO | |
Heating & Cooling (HVAC) | Heating System | Repair / replace Indoor blower motor | blower motor | 650 | 650 | 650 | Repair item may not be specifically identified on the home inspection report; recommend an onsite inspection by a licensed HVAC expert | NO | |
Heating & Cooling (HVAC) | Gas Heating System | Low temperature split. Unit not heating property | gas heating | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Heating & Cooling (HVAC) | Gas Heating System | Add refrigerant (Freon) per pound discount for multiple poundage avg. need 3 pounds | refrigerant, Freon | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Heating & Cooling (HVAC) | Gas Heating System | Replace dual run capacitor | dual run capacitor | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Heating & Cooling (HVAC) | Gas Heating System | Clean indoor coil | indoor coil | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Heating & Cooling (HVAC) | Gas Heating System | Replace contactor | contactor | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Heating & Cooling (HVAC) | Gas Heating System | Replace outdoor fan motor | fan motor | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Heating & Cooling (HVAC) | Gas Heating System | Add refrigerant (Freon) per pound discount for multiple poundage avg. need 3 pounds | refrigerant, Freon | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Heating & Cooling (HVAC) | Air Handler | Seal ductwork | ducts, ductwork | 600 | 600 | 600 | Assumes single location | NO | |
Heating & Cooling (HVAC) | Register | Secure loose register | vent register | 50 | 60 | 70 | NO | ||
Heating & Cooling (HVAC) | Condensate Drain System | Clean condensate pan - part of service - indicator problem wrong in system | condensate pan | 150 | 167.5 | 185 | NO | ||
Heating & Cooling (HVAC) | Condensate Drain System | Adjust drain pan | drain pan | 150 | 167.5 | 185 | NO | ||
Heating & Cooling (HVAC) | Condensate Drain System | Replace drain pan and repair condensate pipes | drain pan, condensate pipes | 375 | 435 | 495 | NO | ||
Heating & Cooling (HVAC) | Condensate Drain System | Clean / repair condensate pipe | condensate pipe | 85 | 155 | 225 | NO | ||
Heating & Cooling (HVAC) | Air Filter | Replace A/C filter | air-conditioning filter, filter | 50 | 50 | 50 | NO | ||
Heating & Cooling (HVAC) | Electrical Disconnect | Install electrical disconnect for HVAC | electrical disconnect | 350 | 437.5 | 525 | Make sure check amperage requirement with licensed contractor | NO | |
Heating & Cooling (HVAC) | Electrical Disconnect | Install correctly sized breaker for A/C disconnect | breaker, A/C disconnect | 120 | 142.5 | 165 | NO | ||
Heating & Cooling (HVAC) | Electrical Wiring | Install AC / Evap system conduit missing | coil, condensing, conduit | 165 | 360 | NO | |||
Heating & Cooling (HVAC) | Refrigerant Lines | Replace missing/damaged insulation at refrigerant (Freon) lines | refrigerant, Freon | 75 | 112.5 | 150 | Qty | NO | |
Heating & Cooling (HVAC) | Controls / Thermostat | Repair thermostat (wired incorrectly) | thermostat, controls | 150 | 250 | 350 | Qty | Assumes using existing thermostat | NO |
Heating & Cooling (HVAC) | Controls / Thermostat | Replace damaged thermostat wire | thermostat, controls | 175 | 175 | 175 | Qty | NO | |
Heating & Cooling (HVAC) | Mechanical Room Ventilation | Repair/replace exhaust (vent) fan | vent fan, exhaust fan | 225 | 300 | 375 | Qty | Assumes easy access | NO |
Interior | Fireplace | Fireplace Inspection | fireplace, fireplace inspection | 125 | 125 | 125 | NO | ||
Interior | Fireplace | Gas logs do not light up | gas logs | 125 | 212.5 | 300 | NO | ||
Interior | Fireplace | FLUE DAMPER ~ Repair | flue damper | 200 | 250 | 300 | NO | ||
Interior | Fireplace | FLUE DAMPER ~ Install | flue damper | 500 | 500 | 500 | NO | ||
Interior | Fireplace | Clean chimney flue | chimney flue | 185 | 192.5 | 200 | NO | ||
Interior | Fireplace | Gas logs with flue damper installed- can not have flue damper | gas logs, flue damper | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Interior | Fireplace | Cracked firebrick | firebrick | 200 | 250 | 300 | NO | ||
Interior | Fireplace | Install spark arrestor | spark arrestor, chimney | 200 | 250 | 150 | NO | ||
Interior | Mold Inspection | Mold Inspection / Air Samples | mold, air samples | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor (Remediation Company) | YES | |
Interior | Cleaning | Move In/ Move Out House Cleaning | house cleaning, move in clean, move out clean, housekeeping, | 225 | 325 | 425 | NO | ||
Interior | Cleaning | Window Cleaning (up to 20 windows) | window cleaning, clean, windows | 160 | 175 | 190 | NO | ||
Interior | Windows | Mini-Blinds on windows (1" blinds) | mini-blinds, window covering | 65 | 65 | 65 | Qty | NO | |
Plumbing System | Inspection / Diagnose Leaks | Investigate and diagnose leaks and water damage | inspection, diagnosis, diagnose, plumbing | 95 | 85 | 125 | Assumes diagnosis only, recommendation and repairs to follow inspection | NO | |
Plumbing System | Water (Main) Supply Pipes | Replace/ install main shut-off valve | shut off valve | 185 | 217.5 | 250 | Assumes up to 1" | NO | |
Plumbing System | Water (Main) Supply Pipes | Install anti-siphon device (back flow preventor) on water supply line | anti-siphon, back flow preventor, supply line | 200 | 275 | 350 | Assumes up to 3/4" | NO | |
Plumbing System | Water (Main) Supply Pipes / Pressure Regulators | Install pressure reducing valve | pressure reducing valve | 290 | 370 | 450 | Assumes up to 1" | NO | |
Plumbing System | Water Supply Pipes / Pressure Regulators | Adjust pressure reducing valve | pressure reducing valve | 95 | 135 | 175 | NO | ||
Plumbing System | Hose Bibs | Add anti-siphon device (vacuum breaker) to existing hose bib | hose bib, anti-siphon valve, vacuum breaker | 40 | 47.5 | 55 | Qty | NO | |
Plumbing System | Hose Bibs | Replace/ repair hose bib (includes anti-siphon device) | hose bib, anti-siphon valve | 125 | 150 | 175 | Qty | Most hose bibs are replaced and not repaired since same pricing | NO |
Plumbing System | Sink Drain Assembly (kitchen, bathroom, laundry room, wet bar) | Repair under sink drain pipe leak (p-trap) | slow drain, pipe leak, p-trap | 85 | 107.5 | 150 | Qty | NO | |
Plumbing System | Sink Drain Assembly (kitchen, bathroom, laundry room, wet bar) | Repair slow drains | slow drain, sink | 65 | 120 | 175 | Qty | NO | |
Plumbing System | Gas Supply Pipes | Install sediment trap | sediment trap | 150 | 200 | 250 | Assumes up to 3/4" | NO | |
Plumbing System | Water Heaters | Service water heater (evaluation and minor repairs) | service water heater, evaluation water heater, minor repairs water heater | 145 | 145 | 145 | Qty | Assumes using existing water lines; recommendation of additional repairs upon site evaluation | NO |
Plumbing System | Water Heaters | Install new Electric Water Heater | water heater, electric | 900 | 1050 | 1200 | Prices include heater and water heater. Does not include drip pan, code upgrades, shut off valves, supply lines. | NO | |
Plumbing System | Water Heaters | Gas Water Heater | water heater, gas | 1000 | 1250 | 1500 | Prices include heater and water heater. Does not include drip pan, code upgrades, shut off valves, supply lines. | NO | |
Plumbing System | Water Heaters | Tankless Water Heater | water heater, Tankless | 2000 | 2500 | 3000 | Prices include heater and water heater. Does not include drip pan, code upgrades, shut off valves, supply lines. | NO | |
Plumbing System | Water Heaters | Evaluate and modify TPR valve drain line | TPR valve, discharge line | 95 | 122.5 | 150 | Units at end of life cycle may leak after valve replacement and may require a new water heater | NO | |
Plumbing System | Water Heaters | Replace TPR valve | TPR valve | 120 | 160 | 200 | Units at end of life cycle may leak after valve replacement and may require a new water heater | NO | |
Plumbing System | Water Heaters | Install TPR valve discharge line | TPR valve, discharge line | 95 | 132.5 | 170 | Units at end of life cycle may leak after valve replacement and may require a new water heater | NO | |
Plumbing System | Water Heaters | Install/replace water shut-off valve on water heater | shut off valve | 95 | 107.5 | 150 | Units at end of life cycle may leak after valve replacement and may require a new water heater | NO | |
Plumbing System | Water Heaters | Adjust water temperature on water heater | water temperature | 65 | 77.5 | 90 | Units at end of life cycle may leak after valve replacement and may require a new water heater | NO | |
Plumbing System | Water Heaters | Replace drain valve at base of water heater | drain valve | 150 | 200 | 250 | NO | ||
Plumbing System | Water Heaters | Drain water heater to clear mineral deposits | drain water heater, mineral deposits | 65 | 65 | 65 | NO | ||
Plumbing System | Water Heaters | Install standard drip (drain) pan under water heater and overflow pipe | drip pan, drain pan, overflow pipe | 160 | 200 | 350 | Assumes draining water heater first | NO | |
Plumbing System | Vent Pipe | Secure water heater single-wall vent pipe (flue pipe) | drip pan, drain pan, overflow pipe, water heater | 65 | 85 | 100 | Assumes a minimum of three sheet metal screws are required at each connection point | NO | |
Plumbing System | Vent Pipe | Install/secure ceiling collar | ceiling collar | 65 | 65 | 65 | NO | ||
Plumbing System | Vent Pipe | Install/secure draft diverter hood | draft diverter hood | 85 | 112.5 | 140 | NO | ||
Plumbing System | Heat Vent / Transite Pipe | Replace transit pipe with a double-walled pipe | transit pipe, heat pipe | 95 | 140 | 185 | NO | ||
Plumbing System | (Under Sink) Water Shut Off Valves and Connectors | Repair/replace water shut-off valves (angle stop) | shut off valve, angle stop | 85 | 102.5 | 120 | Qty | NO | |
Plumbing System | Waste Lines / Drain Waste | Scope waste line to determine condition | waste lines, drain waste | 200 | 250 | 300 | NO | ||
Plumbing System | Waste Lines | Repair leak at ABS drain pipe | drain pipe, ABS drain pipe | 190 | 345 | 500 | Assumes location within 1' of interior of home; Does not include cost to fix wall or other damaged areas | NO | |
Plumbing System | Basements | Evaluate sewage lift pump (sewer ejector pump) | sewage, sewage left pump, sewage ejector pump | 250 | 250 | 250 | NO | ||
Plumbing System | Basements | Replace sewage lift pump (sewer ejector pump) | sewage, sewage left pump, sewage ejector pump | 1400 | 1700 | 2000 | NO | ||
Plumbing System | Water Softener | Install new water softener (whole house) using existing water loop | water softener | 1200 | 750 | 1800 | NO | ||
Plumbing System | Reverse Plumbing | SHOWER ~ Repair hot and cold fixture plumbed in reverse | reverse plumbing, reverse, plumbed | 550 | 762.5 | 975 | Qty | Assumes does not include tile work; tile work to be priced separately | NO |
Attic | Wiring, Junction Boxes, & Conduit | Attic wire cleanup; place exposed wires in conduit | exposed wires, wire clean up | 225 | 225 | 225 | Includes wire splicing and 1 junction box installation | YES | |
Attic | Roof Framing in Attic | Repair cut trusses in attic | trusses | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Attic | Ventilation in Attic | Install vapor barrier | vapor barrier | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Attic | Ventilation in Attic | Install missing insulation in attic ( assumes R-30) | insulation | 650 | 750 | 850 | Assumes 8 -10 inches in depth; final price based on total amount of insulation needed | NO | |
Attic | Ventilation in Attic | Install insulation at attic scuttle hole hatch | insulation, scuttle hole hatch | 65 | 65 | 95 | NO | ||
Attic | Ventilation in Attic | Rough-in exhaust fan vent to vent exterior of house through approved ducts | fans, vents, | 385 | 220 | 460 | Qty | Assumes connection can be made from below; does not include drywall repair or painting | NO |
Attic | Ventilation in Attic | Replace existing exhaust fan vent | exhaust fan, ventilation fan | 220 | 220 | 220 | Qty | NO | |
Attic | Ventilation in Attic | Extend exhaust fan ductwork to exterior | exhaust fan, ventilation fan | 285 | 337.5 | 390 | Qty | NO | |
Interior | Windows | Replace/repair window balances | window balances | 150 | 150 | 150 | Qty | Does not include cost of material; Spring is another term used for Balance or Counter Balance | NO |
Interior | Windows | Replace window trim | window trim, frame | 225 | 225 | 225 | Qty | Assumes up to 24 sq. ft. window; standard trim and painting | NO |
Interior | Windows | Replace bent, missing and broken window screens | window screens. Screens | 25 | 50 | 75 | Qty | NO | |
Interior | Windows | Replace glass up to 12 sq. ft. | glass window | 265 | 297.5 | 330 | Qty | Assumes dual pane; standard windows; may not include gases or low E coating | YES |
Interior | Windows | Repair window sill/damage/rotted wood (small area - up to 24 sq. ft.) | window sill | 90 | 170 | 250 | Qty | Assumes dual pane; standard windows; may not include gases or low E coating | NO |
Interior | Windows | Repair window sill/damage/rotted wood (entirely rotted sill; rebuilding entire window sill) | window sill | 325 | 450 | 575 | Qty | Assumes rebuilding entire window sill | NO |
Interior | Windows | Repair broken seals; install a new sash (frame preserved) | broken seals, sash | 100 | 175 | 250 | Qty | NO | |
Interior | Windows | Repair lock on window | locks | 95 | 140 | 185 | Qty | Assumes hardware/ parts are available and reasonably priced | YES |
Interior | Windows | Replace window cranks | cranks | 85 | 90 | 95 | Qty | NO | |
Interior | Doors | Repair/replace/adjust door handle/latch | door handle, door latch | 75 | 125 | 105 | Qty | NO | |
Interior | Doors | Replace door casing (trim) | door casing | 275 | 312.5 | 350 | Qty | Removal of old trim, new trim, caulking, does not include painting (see Interior /Paint for quote) | NO |
Interior | Doors | Install new interior door | door, interior door | 225 | 330 | 435 | Qty | Assumes replace with prehung hollow core door; paint and trim | NO |
Interior | Doors | Repair loose hinges | hinges | 95 | 110 | 125 | Qty | NO | |
Interior | Doors | Repair door that sticks in frame | door sticks, door frame | 95 | 110 | 125 | Qty | NO | |
Interior | Closets | Install clothes rod in closet | rod, clothes rod | 65 | 70 | 75 | Qty | NO | |
Interior | Ceiling / Walls / Floors | Peeling of drywall finish at garage ceiling; correct | drywall | 475 | 475 | 475 | Assume up to 10'x 6' area; includes painting | NO | |
Interior | Ceiling / Walls / Floors | Tile repair | for tiles, flooring, | 75 | 75 | 75 | Qty | Customer provided tile | NO |
Interior | Ceiling / Walls / Floors | Install new grout in tile areas where missing | tile grout | 200 | 225 | 250 | Color may not match to existing grout | NO | |
Interior | Ceiling / Walls / Floors | Stretch carpeting and attach to tack strips | carpet stretching, tack strips | 95 | 122.5 | 150 | Qty | NO | |
Interior | Ceiling / Walls / Floors | Repair damaged drywall (normally includes light texturing and painting touch-up) | drywall, drywall repair | 150 | 222.5 | 295 | Qty | Texturing is to match existing texture in home; Paint may have possible variation in color | NO |
Interior | Ceiling / Walls / Floors | Replace damage drywall (includes cutting out damaged area, replace, texturing and painting) | drywall, drywall repair | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Interior | Ceiling / Walls / Floors | Removal of popcorn ceilings | popcorn ceilings | 1.85 | 1.85 | 1.85 | Sq. Ft. | NO | |
Interior | Ceiling / Walls / Floors | Texturing after removing popcorn ceilings | popcorn ceilings | 3.85 | 3.85 | 3.85 | Sq. Ft. | NO | |
Interior | Paint | Touch-up paint in areas of drywall repair | paint, painting, touch-up paint, walls | 95 | 95 | 125 | Qty | Assumes less than 36 sq. ft. | NO |
Interior | Paint | Touch-up paint interior ceiling | paint, painting, touch-up paint, ceiling | 145 | 145 | 145 | Qty | Assumes less than 36 sq. ft. | NO |
Interior | Paint | Paint interior walls | paint, painting, walls | 1.2 | 1.3 | 1.4 | Sq. Ft. | NO | |
Interior | Smoke & Carbon Detectors | Replace smoke detectors (assumes existing wiring) | smoke detector | 85 | 95 | 105 | Qty | Assumes using existing wiring | YES |
Interior | Smoke & Carbon Detectors | Replace CO detector | carbon monoxide, detector | 85 | 95 | 105 | Qty | Assumes using existing wiring | YES |
Interior | Smoke & Carbon Detectors | Replace smoke detector cover | smoke detector | 45 | 60 | 75 | Qty | NO | |
Interior | Fixtures | Secure loose lighting fixture | lighting fixture | 65 | 75 | 85 | Qty | NO | |
Kitchen | Appliances | DISHWASHER ~ Repair high loop at drain line on dishwasher | high loop, drain line, dishwasher | 105 | 105 | 105 | NO | ||
Kitchen | Appliances | DISHWASHER ~ Replace rollers on dishwasher | rollers, dishwasher | 225 | 225 | 225 | May require replacement of unit | NO | |
Kitchen | Appliances | DISHWASHER ~ Replace racks on inside of dishwasher | racks, dishwasher | 175 | 212.5 | 250 | NO | ||
Kitchen | Appliances | DISHWASHER ~ Secure dishwasher to cabinet, counter | dishwasher | 85 | 105 | 125 | NO | ||
Kitchen | Appliances | COOKTOP/ RANGE/ OVENS ~ Install anti-tip (device) bracket at range | anti-tip, bracket, range, stove | 125 | 125 | 125 | NO | ||
Kitchen | Appliances | COOKTOP/ RANGE/ OVENS ~ Repair gas stove burners | stove burner, range | 150 | 180 | 210 | Qty | NO | |
Kitchen | Appliances | COOKTOP/ RANGE/ OVENS ~ Repair electric oven heating element | electric oven, heating element | 225 | 270 | 315 | Qty | NO | |
Kitchen | Appliances | COOKTOP/ RANGE/ OVENS ~ Repair oven handle | oven handle | 110 | 120 | 130 | NO | ||
Kitchen | Appliances | COOKTOP/ RANGE/ OVENS ~ Repair oven door | oven door | 150 | 237.5 | 325 | NO | ||
Kitchen | Appliances | GARBAGE DISPOSAL ~ Replace disposal | garbage disposal | 225 | 262.5 | 300 | NO | ||
Kitchen | Appliances | GARBAGE DISPOSAL ~ Install strain relief on garbage disposal electrical connection | strain relief, garbage disposal | 125 | 125 | 125 | NO | ||
Kitchen | Appliances | MICROWAVE VENTILATION ~ Repair external microwave fan | microwave fan, microwave ventilation | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Kitchen | Appliances | REFRIGERATOR ~ Repair ice maker | refrigerator, ice maker | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Kitchen | Sinks | Tighten kitchen faucet | faucet | 75 | 75 | 75 | Qty | NO | |
Kitchen | Sinks | Install /replace kitchen sink faucet | faucet | 165 | 175 | 185 | Assumes customer supplied faucet | NO | |
Kitchen | Sinks | Repair leak at kitchen faucet | leak, leaking, faucet | 125 | 135 | 145 | Assumes replace only | NO | |
Kitchen | Sinks | Repair under sink drain pipe leak (p-trap) | slow drain, pipe leak, leakage | 65 | 107.5 | 150 | Qty | NO | |
Kitchen | Sinks | Repair slow drains | slow drains, faucet leaks | 65 | 75 | 85 | Qty | NO | |
Kitchen | Sinks | Replace spray wand | spray wand | 150 | 150 | 150 | NO | ||
Kitchen | Sinks | Replace kitchen sink stopper | sink stopper | 75 | 75 | 75 | NO | ||
Kitchen | Sinks | Repair faucet - difficult to rotate | faucet | 150 | 150 | 150 | NO | ||
Kitchen | Cabinets | Repair cabinet base | cabinet base | 69 | 69 | 69 | Qty | Assumes cabinet is repairable | NO |
Kitchen | Cabinets | Replace/adjust broken drawer slides | drawers, drawer slides | 110 | 110 | 110 | Assumes 2 hours of labor | NO | |
Kitchen | Countertops | Caulking of separation/ gaps at countertops | countertops | 125 | 150 | 150 | Assumes caulking of countertop only | NO | |
Kitchen | Ventilation | Rough-in hood vent system in kitchen; including fan, switch and ducting to exterior | ventilation, vent hood, exterior, kitchen | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Kitchen | Ventilation | Vent existing hood vent to exterior | ventilation, vent hood, exterior, kitchen | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Laundry Area | Washer / Dryer | Repair dryer ventilation housing at hose attachment | dryer ventilation | 125 | 125 | 125 | NO | ||
Laundry Area | Washer / Dryer | Replace exterior dryer vent cover | dryer vent cover | 125 | 225 | 175 | Assume replace vent between dryer and wall only | NO | |
Laundry Area | Washer / Dryer | Clean dryer vent duct | dryer vent duct | 120 | 135 | 150 | NO | ||
Laundry Area | Ventilation | Replace existing exhaust fan | ventilation fan | 225 | 850 | 300 | NO | ||
Laundry Area | Ventilation | Rough-in exhaust fan system in laundry room; including fan, switch and ducting to exterior | ventilation, exhaust fan, exterior, laundry | 850 | 975 | 1100 | NO | ||
Laundry Area | Ventilation | Vent existing exhaust fan to exterior | ventilation, exhaust fan, exterior, laundry | 320 | 357.5 | 395 | NO | ||
Garage | Overhead Garage | Remove and replace perimeter seal at garage door - 2 car garage; replace only | garage door perimeter seal | 90 | 132.5 | 175 | Does not include painting | NO | |
Garage | Overhead Garage | Replace garage door bottom seal | garage door bottom seal | 75 | 85 | 95 | Assumes 2-car garage; Bottom Seal is another term for Garage Door Bottom Seal | NO | |
Garage | Overhead Garage | Replace garage door open/close panel on wall | garage door button | 125 | 125 | 125 | Assumes 2-car garage; Bottom Seal is another term for Garage Door Bottom Seal | NO | |
Garage | Inspection | SERVICE PACKAGE ~ Inspect garage springs, adjust back-up/ reverse sensors, garage door features, lubrication, (tune-up); plus recommendations of further repairs needed | garage spring, garage sensor, inspection, tune-up | 169 | 160 | 229 | Assumes garage door opener is operational | YES | |
Garage | Overhead Garage | Install infrared eye beam sensors for garage doors (back-up / reverse sensors) | infrared eye beam, back up reverse sensors | 105 | 135 | 165 | YES | ||
Garage | Overhead Garage | Replace broken garage door spring - traditional door with dual springs | garage door spring | 200 | 200 | 200 | YES | ||
Garage | Overhead Garage | Replace broken garage door spring - heavy duty door or overlay door - typically have 4 springs | garage door spring | 400 | 400 | 400 | YES | ||
Garage | Overhead Garage | Replace standard two car garage door | two car garage door | 1500 | 1650 | 1800 | Qty | Assumes no garage door opener included, no painting (see Garage/Paint for quote) | NO |
Garage | Overhead Garage | Replace standard one car garage door | one car garage door | 650 | 750 | 850 | Qty | Assumes no garage door opener included, no painting (see Garage/Paint for quote) | NO |
Garage | Overhead Garage Door | Repair garage door; rebuild of all moving parts (all tracks, chain, rollers) | garage door rebuild | 350 | 350 | 350 | YES | ||
Garage | Overhead Garage Door | Replace garage door panel | garage door panel | 200 | 400 | 600 | Qty | Assumes no painting included; Cost may vary based on make and manufacturer of panel, thickness of panel, and build (such as insulation and steel backing) | NO |
Garage | Paint | Paint overhead garage door | garage door | 225 | 225 | 225 | Qty | Up to 4 sections | NO |
Garage | Overhead Garage Door | Remove and replace garage door opener (Basic Liftmaster, 2 remote per opener) | garage door opener, garage door motor | 325 | 437.5 | 550 | Qty | YES | |
Garage | Fire Separation | Make entry door from garage to house self-closing | fire door, garage door to house, fire separation door, self closing, self latching, latch | 150 | 150 | 150 | Assumes install 1 self closing hinge | YES | |
Garage | Fire Separation | Replace weather stripping on garage/fire separation door between house and garage | weather stripping, fire door, garage door to house, fire separation door | 125 | 150 | 175 | YES | ||
Garage | Fire Separation | Replace door from garage to home with solid core door | fire door, garage door to house, fire separation door | 575 | 687.5 | 800 | Assumes Includes door, trim and painting | YES | |
Garage | Fire Separation | Install fire-rated material at pull down ladder | garage pull down ladder | 140 | 140 | 140 | YES | ||
Garage | Fire Separation | Install fire - rated material attic access (scuttle hole) | fire rated material, attic access, scuttle door | 140 | 140 | 140 | YES | ||
Garage | Paint | Paint fire-rated solid core door (both sides) | fire rated door | 200 | 200 | 200 | NO | ||
Garage | Ceiling / Walls / Floors | Repair peeling of drywall finish at garage ceiling | drywall, garage ceiling | 475 | 475 | 475 | Assume up to 10'x6" area; includes painting | NO | |
Garage | Paint | Garage touch -up paint (ceiling) | touch-up paint, garage ceiling | 145 | 235 | 325 | Color may vary and may not match | NO | |
Garage | Ceiling / Walls / Floors | Repair holes in drywall material | garage walls, garage ceiling, drywall | 150 | 150 | 150 | Does not include cost of material; Assumes no painting included | NO | |
Garage | Ceiling / Walls / Floors | Chemical power wash concrete in garage | power wash garage | 225 | 250 | 275 | NO | ||
Pool / Spa | Inspection - Pool | Pool Inspection (check of all major parts of system pool equipment, check the timer, backwash pool, fix up to one leak - up to 1 hour of labor and minor parts - further recommendations) | pool inspection | 250 | 495 | 250 | Assumes pool specialist will evaluate entire system for repairs and deficiencies to recommend further action necessary | NO | |
Pool / Spa | Interior Finish | Repair pool's plaster deterioration and bubbled areas | pool plaster, pool | 5 | 5 | 5 | Sq. Ft. | Assumes a minimum of 50 sq. ft. | NO |
Pool / Spa | Deck / Steps / Coping | Repair decking | pool decking, pool cool deck, pool | 5 | 5 | 5 | Sq. Ft. | Assumes a minimum of 50 sq. ft. | NO |
Pool / Spa | Skimmer & Cleaning System | Install anti-siphon device (back flow preventor) | anti-siphon, back flow preventor, pool | 50 | 100 | 150 | NO | ||
Pool / Spa | Skimmer & Cleaning System | Repair pool cleaning pop ups so that they function | pool, cleaning pop ups, pool | 45 | 45 | 45 | Qty | NO | |
Pool / Spa | Skimmer & Cleaning System | Repair pool cleaning system | pool cleaning, pool | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Pool / Spa | Drain Covers | Replace main drain cover with an anti-vortex cover (anti-entrapment)- temperature above 90 degrees | main drain cover, anti-vortex cover, anti-entrapment | 250 | 95 | 275 | YES | ||
Pool / Spa | Drain Covers | Replace main drain cover with an anti-vortex cover (anti-entrapment)- winter time | main drain, vortex cover, anti-entrapment | 500 | 500 | 500 | YES | ||
Pool / Spa | Pool Light | Repair pool light- inoperable | pool light, pool | 195 | 397.5 | 600 | Price will vary based on where canister is compromised; price assumes canister not compromised; price can vary to $750 | YES | |
Pool / Spa | Pool Light | Add GFCI in pool light circuit | pool light, pool, GFCI | 125 | 162.5 | 200 | YES | ||
Pool / Spa | Pool Motor / Pump | Re-plumb pump with three way valve | pool pump, pool valve | 225 | 225 | 225 | NO | ||
Pool / Spa | Pool Motor / Pump | Secure loose bonding wire at pool motor pump | pool pump, pool motor, bonding wire, bond wire, pool | 110 | 125 | 140 | YES | ||
Pool / Spa | Pool Motor / Pump | Install bond wire at pool pump/motor | pool pump, pool motor, bonding wire, bond wire, pool | 90 | 105 | 120 | YES | ||
Pool / Spa | Pool Motor / Pump | Repair leaks at pump and equipment | pool pump, pool equipment, pool | 95 | 172.5 | 250 | NO | ||
Pool / Spa | Filter | Service filter for gaskets | pool filter, pool gaskets, pool | 35 | 50 | 65 | NO | ||
Pool / Spa | Filter | Repair/ replace leak at pool filter O-ring (seal) | O-ring, seal, pool | 55 | 70 | 85 | NO | ||
Pool / Spa | Heater Issues | Repair pool heater | pool heater, pool | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Pool / Spa | Heater Issues | Replace pool heater | pool heater, pool | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Pool / Spa | Cleaning | Acid wash pool | acid wash, pool | 450 | 550 | 650 | NO | ||
Pool / Spa | Automatic Filler | Repair/replace pool automatic filler (back wash) valve | automatic filler, valve, pool | 110 | 110 | 110 | NO | ||
Pool / Spa | Pool Fence | Install fence around pool; install a barrier or fence between home and pool area | pool fence, pool gate, pool barrier | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | YES | |
Pool / Spa | Pool Fence | Repair pool gate latch | pool gate, latch, self closing | 120 | 120 | 120 | Assumes new hardware is not needed | YES | |
Pool / Spa | Water Feature Pump | Replace and ground the water feature pump | water feature, pump | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Pool / Spa | Timers | Install clips/tabs (trippers) on pool timer | clips, tabs, timer, wheel timer, pool timer, pool | 35 | 50 | 65 | NO | ||
Pool / Spa | Timers | Replace cover on timer | cover, timer, pool timer, pool | 95 | 130 | 165 | Assumes must purchase a new timer; covers not sold separately | NO | |
Pool / Spa | Timers | Replace timer | wheel timer, timer, pool timer, pool | 95 | 147.5 | 200 | NO | ||
Pool / Spa | Timers | Replace yellow wheel timer mechanism | wheel timer, timer, pool timer, pool | 80 | 80 | 80 | NO | ||
Pool / Spa | Inspection - Spa | Evaluate whether spa is operational | spa inspection, spa operational | 135 | 135 | 135 | Assumes further recommendations for additional repairs will be provided | NO | |
Bathrooms | Counters | Separation/ gaps need to sealed at countertops | gaps, seal, countertop | 150 | 150 | 150 | Assumes caulking of countertop only | NO | |
Bathrooms | Sinks | Tighten bathroom faucet at sink | bathroom faucet | 55 | 55 | 55 | NO | ||
Bathrooms | Sinks | Replace bathroom sink | bathroom sink | 185 | 185 | 185 | Does not include countertop repair if needed | NO | |
Bathrooms | Sinks | Repair under sink drain pipe leak (p-trap) | slow drain, pipe leak, leakage | 65 | 107.5 | 150 | Qty | NO | |
Bathrooms | Sinks | Repair slow drains | slow drains, faucet leaks | 65 | 75 | 85 | Qty | NO | |
Bathrooms | Sinks | Repair faucet leaks | faucet leaks, bathroom faucet leak | 180 | 215 | 250 | Qty | Assumes needs a cartridge replacement | NO |
Bathrooms | Bathtub & Shower | Repair loose bathtub | bathtub, tub | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Bathrooms | Bathtub & Shower | Repair diverter on bathtub/shower spouts | diverter, tub spout, bathtub spout | 65 | 72.5 | 80 | Qty | NO | |
Bathrooms | Bathtub & Shower | Replace diverter on bathtub/shower spouts | diverter, tub spout, bathtub spout | 165 | 195 | 225 | Qty | NO | |
Bathrooms | Bathtub & Shower | Repair leak on bathtub spout | bathtub leak, tub faucet cartridge | 155 | 170 | 185 | Qty | NO | |
Bathrooms | Bathtub & Shower | Install new bathtub spout | bathtub spout, bathtub, tub | 65 | 65 | 65 | Qty | NO | |
Bathrooms | Bathtub & Shower | Repair shower head leak | shower head | 85 | 85 | 85 | Qty | NO | |
Bathrooms | Bathtub & Shower | Replace shower head | shower head | 125 | 125 | 125 | Qty | May require cartridge replacement | NO |
Bathrooms | Bathtub & Shower | Repair caulking around bathtub spout | caulk, caulking, tub spot | 150 | 150 | 150 | Qty | NO | |
Bathrooms | Bathtub & Shower | Repair bathtub/shower faucet handle; not emitting hot water when turned to hot side | tub faucet, shower faucet | FELC | FELC | FELC | Not eligible for a Quik Quote; Further Evaluation needed from a Licensed Contractor | NO | |
Bathrooms | Bathtub & Shower | Secure bathtub/shower valve to wall | tub, shower valve | 85 | 85 | 85 | Qty | NO | |
Bathrooms | Bathtub & Shower | Repair slow drain in bathtub | slow drain, bathtub, tub | 65 | 55 | 85 | Qty | NO | |
Bathrooms | Bathtub & Shower | SHOWER ~ Repair hot and cold fixture plumbed in reverse | reverse plumbing, reverse, plumbed | 550 | 762.5 | 975 | Assumes does not include tile work; tile work to be priced separately | NO | |
Bathrooms | Bathtub & Shower | FAUCET ~ Repair hot and cold fixture plumbed in reverse (c-cartridge) | reverse plumbing, reverse, plumbed | 190 | 225 | 260 | Qty | NO | |
Bathrooms | Bathtub & Shower | Repair, grout, caulk at bathtub/shower fixtures, wall transitions and floor transitions | tile grout, caulk, caulking, shower | 150 | 185 | 220 | Assumes 2 hours of labor | NO | |
Bathrooms | Bathtub & Shower | Replace valve not supplying hot water | valve, shower | 975 | 975 | 975 | NO | ||
Bathrooms | Bathtub & Shower | Replace missing drain stop in bathtub | drain stop, bathtub, tub | 45 | 55 | 65 | Qty | NO | |
Bathrooms | Bathtub & Shower | Replace bond wire to the whirlpool pump motor in bathroom | bond wire, pump motor, whirlpool pump | 130 | 130 | 130 | Qty | NO | |
Bathrooms | Drain Cleaning | Slow drain in shower | shower drain | 225 | 225 | 225 | Qty | NO | |
Bathrooms | Drain Cleaning | Drain clean-outs | drain clean outs, clogged drains | 95 | 110 | 125 | Assumes multiple places are experiencing slow drains | NO | |
Bathrooms | Toilets | Repair leak at toilet floor/wall seal | leaking toilet, seal | 180 | 220 | 260 | Qty | Assumes replace wax ring only | NO |
Bathrooms | Toilets | Secure loose toilet to floor or wall | toilet | 150 | 150 | 150 | Qty | NO | |
Bathrooms | Toilets | Replace tank seal on toilet | tank seal, toilet | 225 | 225 | 225 | Qty | Assumes rebuild tank | NO |
Bathrooms | Toilets | Replace flush handle on toilet | flush handle, toilet | 75 | 75 | 75 | Qty | NO | |
Bathrooms | Toilets | Repair toilets that are running | toilet | 120 | 172.5 | 225 | Qty | Assumes rebuild tank | NO |
Bathrooms | Toilets | Secure loose toilet tank to base | toilet tank | 150 | 165 | 180 | Qty | Assumes rebuild tank | NO |
Bathrooms | Toilets | Replace leaking toilet tank bolt seals | toilet tank, bolt seals | 130 | 225 | 175 | Qty | Assumes rebuild tank | NO |
Bathrooms | Toilets | Repair caulking around toilet base | caulk, caulking, toilet base | 125 | 125 | 125 | Qty | NO | |
Bathrooms | Cabinets | Repair cabinet base | cabinet base | 185 | 69 | 225 | Qty | Assumes cabinet can be repaired | NO |
Bathrooms | Cabinets | Replace/adjust broken drawer slides | drawers, drawer slides | 110 | 110 | 110 | NO | ||
Bathrooms | Ventilation | Replace ventilation fan cover | ventilation fan cover | 75 | 75 | 75 | Qty | NO | |
Bathrooms | Ventilation | Replace ventilation (exhaust) fan | exhaust fan, ventilation | 240 | 270 | 300 | Qty | Assumes using existing housing and electrical; does not include drywall repair or painting (see Interior/ Ceiling/Walls/Flooring) | NO |
Bathrooms | Ventilation | Rough-in exhaust fan system in bathroom; including fan, switch and ducting to exterior | exhaust fan vents, ventilation | 850 | 975 | 1100 | Qty | Assumes connection can be made from below; does not include drywall repair or painting (see Interior/ Ceiling/Walls/Flooring) | NO |
Bathrooms | Ventilation | Vent existing exhaust fan to exterior | exhaust fan vents, ventilation | 320 | 357.5 | 395 | Qty | NO | |
Fire Sprinkler System | Fire Sprinklers | Inspection | fire sprinkler inspection | 85 | 85 | 85 | YES | ||
Fire Sprinkler System | Fire Sprinklers | Replace fire sprinklers (Includes labor and sprinkler head) | fire sprinklers | 85 | 85 | 85 | QTY | Does not include drywall repair or painting (see Interior/ Ceiling/Walls/Flooring) | YES |
Pest Control | Termite Treatments | Termite Treatment with 1 year warranty | termite | 2 | 2 | 2 | LF | Linear Feet obtained from County Accessor's Office | NO |
Pest Control | Termite Treatments | Termite Treatment with 2 year warranty | termite | 2.25 | 2.25 | 2.25 | LF | Linear Feet obtained from County Accessor's Office | NO |
Pest Control | Termite Treatments | Termite Treatment with 3 year warranty | termite | 2.5 | 2.5 | 2.5 | LF | Linear Feet obtained from County Accessor's Office | NO |
Pest Control | Termite Treatments | Termite Treatment with 5 year warranty | termite | 3 | 3 | 3 | LF | Linear Feet obtained from County Accessor's Office | NO |
Pest Control | Rodents / Pests Treatments | Treat and set traps on property for pests / rodents | rodents, pest control, traps | 185 | 225 | 265 | NO | ||
technical aspects of job | |||||||||
market price variation | |||||||||
location |